Revit could not load C:\Program Files\Autodesk\Revit 2024\EnergyAnalysisDB.dll

December 18, 2023 Paul Sills

Issue:
When starting Revit 2024 an error “Revit could not load C:\Program Files\Autodesk\Revit 2024\EnergyAnalysisDB.dll and then closes when selecting OK

Causes:
When uninstalling Revit 2024 using the Autodesk uninstaller located in folder C:\ProgramData\Autodesk\Uninstallers can cause this issue after reinstalling Revit 2024

Solution:
When receiving the error, you have the option to select Help which opens:
Revit cannot be launched when DLL file is not loaded.
During troubleshooting this error, we tried uninstalling and reinstalling Microsoft C++, tried uninstalling and reinstalling Revit 2024, and ran the window updates and still received the dll issue.
The current fix for this issue that we have found is to simply uninstall Revit and Autodesk Revit Unit Schemas 2024 using Programs and Features

or through Apps & features (do not use the UninstallHelper.exe) and then reinstalling Revit 2024 seems to fix the issue. To navigate to Apps and features, go to settings, then apps, and then Apps and features

About the Author

Paul Sills

Sr. Support Specialist<br><br>Paul is responsible for client technical support as well as the set-up and configuring of plotters; support and service calls; and the installation, demonstration, and education of clients in AutoCAD, AutoCAD Architecture, AutoCAD MEP, AutoCAD P&ID, Advance Steel, Navisworks, Raster Design, Revit Architecture, Revit MEP, Revit Structure and 3D Studio MAX. He draws upon his years of experience as a technical engineer to assist customers in the creation and implementation of standards, the set-up of plotter and pen styles and the creation of custom blocks.

Follow on Linkedin More Content by Paul Sills
Previous Article
Setting up a new Project in Autodesk Forma
Setting up a new Project in Autodesk Forma

A seat of Autodesk Forma is included with the AEC Collection subscription to be used to create a conceptual...

Next Article
IMAGINiT Vault Backup Report is received in email with Chinese characters in place of table border characters.
IMAGINiT Vault Backup Report is received in email with Chinese characters in place of table border characters.

IMAGINiT Vault Backup Report is received in email with Chinese characters in place of table border characte...

×

Get Tips Delivered.

Subscribe to Email Updates.

First Name
Last Name
Country
Thank you!
Error - something went wrong!