Vault Copy Design Action Rules do not seem to work for multiple property updates

March 9, 2023 Bob Felton

Issue: 

In the Vault's current Copy Design (but not the old Copy Design) when several properties need to be updated during the copy operation, it doesn't appear that any properties after the first one are updated.

 

 

Causes:

The procedure that seems like it should work actually does not work. Only the first rule that is listed gets acted upon.

 

Solution:

A single rule should have multiple property updates listed, like this.

 

 

About the Author

Bob Felton

Sr. Technical Support Specialist, Manufacturing<br><br>Bob Felton has been supporting Autodesk products for over 25 years including core AutoCAD, P&ID, Plant 3D, AutoCAD for Mac, AutoCAD Mechanical, and Vault. His background is in graphics with an Applied Sciences degree and ten years manufacturing experience drafting, as well as technical illustration, image editing, and even patent drafting.